RAIS RONDO User Manual Page 4

  • Download
  • Add to my manuals
  • Print
  • Page
    / 44
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 3
4
US English User Manual for RAIS Rondo, RAIS Mino II and RAIS Mino II Soapstone
Introduction
Congratulations on the purchase of your new RAIS woodburning
stove.
A RAIS woodburning stove is more than just a source of heat, it is a
symbol of the emphasis you put on decorating your home with superi
-
orly designed high-quality products.
PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND
USE YOUR NEW RAIS STOVE. FAILURE TO FOLLOW INSTRUC-
TIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY,
OR EVEN DEATH.SAVE THIS MANUAL AND KEEP IT HANDY FOR
EASY REFERRAL.
Safety and environmental testing
The RAIS Rondo/Mino Series stoves have been tested by OMNI-Test
Laboratories, Inc., Beaverton, Oregon and are listed to UL 1482 and
ULC S627. They are also EPA certified and meet the stringent WA
State Environmental standards.
For future reference, please write down the production number of
your RAIS woodburning stove here. The number must be stated in all
inquiries or complaints concerning this product.
Warranty
We offer a five-year warranty on your RAIS stove. The warranty covers
any defects in materials or workmanship. However, it does not cover
damage from misuse or neglect, and the glass, gaskets and firebricks
are not covered either.
Specifications:
RAIS Mino II RAIS Mino II
Soapstone
RAIS Rondo
Weight
265 lbs (120 kg) 456 lbs (207 kg) 304 lbs (138 kg)
Stove exterior: Width/depth/height (inches)
20.1 / 18.1 / 39.4 21.1 / 19.0 / 40.4 19.3 / 19.3 / 40.6
Firebox interior Width/depth/height (inches)
13.2 / 11.4 / 13.6
Heating capacity at -20°C/-4°F Approximately 100 m² / 1100 Square Feet
Recommended wood quantity:
2-3 logs of 10” in length each
1.5 kg / 3.3 lbs
Intermittent operation:
Stoke the stove every three hours
Flue gas mass flow:
4.7 grams per second
Flue gas temperature:
246°C / 475°F
Single wall connector stove pipe: 6” (15 cm)
Chimney pipe - class A, UL-103 HT:
6” (15 cm)
Optimal thermal output : 17 kBTU (5,1 kW)
Min./Max. output (kW): 12 - 23 kBTU (3.4 - 6.6 kW)
Minimum stove draft pressure at above output:
0.048”WC (12 Pa)
Tested EPA emission particulate rate:
4.3 grams/hour
Page view 3
1 2 3 4 5 6 7 8 9 ... 43 44

Comments to this Manuals

No comments