ATTENTION!
For the sake of adjustment options for set screws, level foundation
must be min. 5 mm below the horizontal edge in front.
Brick
Non-combustible
panel
Built-in dimensions - wall opening
The wall opening is min. 613mm x 473mm (height x width).
The depth is min. 475 mm (non-combustible panel) and min. 425mm (brick).
A fireplace insert must never be built in tightly as steel expands during heating.
Air system If an air system is fitted, make sure that
the stove damper is supplied with fresh
air from the outside, either through the
back or bottom side of the stove.
For correct function of the air system,
no negative pressure must occur in the
housing.